Model PCV
Power Conditioners
Super Isolation Transformer  

Single Phase  
0.5 to 5 kVA
Model PCV
Single Phase  0.5  to 5 kVA

H Models -
220V; 230V or 240V

L Models -
100V; 110V or 120V  

Input Swing Range:  
-20% +15% or +/-45%

Typical Applications include:

●  Computers
●  Medical Equipment
●  Electronics Equipment
●  Testing Equipment
●  Laboratory Equipment
●  POS Terminals
●  Process Control Systems
●  Communication Systems
●  TV/Radio Broadcasting
●  Elevators / Lifts
●  Audio / Video Systems
●  Security Systems
●  Production Line
●  CNC Equipment
●  SMT Equipment
Single phase AC Power Conditioners -  500VA to 5000 VA

Endurable Power Conditioning Protection against Voltage Fluctuation and
Line Disturbances - Wide Input Range

  • Range 0.5 to 5 KVA
  • Input Swing Range -20% +15% (±45%)
  • Output Voltage Accuracy ±0.5%, (±5%)
  • High Efficiency: Better than 90%
  • Isolation transformer
    - Common mode noise 110db
    - Normal mode noise 60db
  • Spike Suppression
    - Protects loads against high-energy surges
    and lightning strikes
  • Energy Storage
    -Ride through - No loss of output voltage for power
    losses of up to 3msecs
  • Standard Features
    Input circuit breaker
    Voltmeter ( 500Va ~1000Va)
    Voltmeter/Ammeter (2Kva ~ 5KVA)
  • Compliance with International Standards
    BS EN50081-1;2/IEC 61000-4-3;4
    BS EN5490/IEC 60529
  • CE Conformity
Model OPCV
Outdoor IP 54


  • AC mains voltage fluctuations, common mode noise, and high energy transients can
    cause equipment to behave erratically and malfunction. Some equipment will even
    breakdown because of these problems. Failure to keep voltage stable can result in costly

  • Ashley-Edison PCV AC Power Line Conditioners are designed to maintain the mains
    voltage constant at all times. Based upon a super-isolation transformer design, the
    conditioners will ensure that the output voltage remains stable should the incoming mains
    voltage drift high or low.

  • PCV conditioners are charaterised by their extreme tolerance for very wide input
    fluctuations, even when the input voltage drops to as low as 45%, the output will be
    maintained at nominal voltage ± 5%.

  • The design also delivers the ability to withstand a ride-through when there is a very short
    power failure - with output still being maintained for 3 msecs. This feature is extremely
    useful when there are frequent short breaks or voltage dips in the mains supply. With the
    ability to withstand high instantaneous overloads without causing any damage, the super-
    isolation transformer will suppress any lightning spikes or surges

For Further details or discuss your individual requirements, please contact us.
Download the PDF Fact Sheets:


OPCV-S40      Email Us
You may need Adobe Acrobat Reader to view these documents. If you do not have this installed,
you can
download it free from Adobe's website
© 2009 Ashley-Edison